Turtle Tough HACH Compatible pH Sensor

HACH compatible pH Sensor Outlasts OEM by up to 10 times Differential Preamplifier (Optional) 6m cable RYTON with ¾” Front End – 1” MNPT Back End MNPT -5°C to 105°C Double Junction (Triple optional) Coat resistant materials reduce fouling Acid/Fluoride Resistant Ammonia, Chlorine and Sulphide Gas Resistant High Capacity KYNAR Reference

ABB Compatible pH Sensor

ABB compatible pH Sensor Outlasts OEM by up to 10 times 6m cable RYTON with ¾” MNPT Front & Back End -5°C to 105°C Double Junction (Triple optional) Coat resistant materials reduce fouling Acid/Fluoride Resistant Ammonia, Chlorine and Sulphide Gas Resistant High Capacity KYNAR Reference

Endress + Hauser Compatible pH Sensor

Endress + Hauser compatible pH Sensor Outlasts OEM by up to 10 times 6m cable RYTON with ¾” MNPT Front & Back End -5°C to 105°C Double Junction (triple optional) Coat resistant materials reduce fouling Acid/Fluoride Resistant Ammonia, Chlorine and Sulphide Gas Resistant High Capacity KYNAR Reference Special glass to suit Endress + Hauser

Foxboro Compatible pH Sensor

6m cable RYTON with ¾”  Front End – 1” Back End MNPT -5°C to 105°C Immersion or Submersible (optional) Double Junction Acid/Fluoride Resistant Ammonia, Chlorine and Sulphide Gas Resistant High Capacity KYNAR Reference Proprietary toughened glass Options: High Impact, Solvent Resistant, Extreme Dehydration Integrated pre-amplifier required for certain models

Rosemount Compatible pH Sensor

6m cable RYTON with ¾”  Front End – 1” Back End MNPT -5°C to 105°C Immersion or Submersible (optional) Double Junction Acid/Fluoride Resistant Ammonia, Chlorine and Sulphide Gas Resistant High Capacity KYNAR Reference Proprietary toughened glass Options: High Impact, Solvent Resistant, Extreme Dehydration Integrated pre-amplifier required for certain models

Yokogawa Compatible pH Sensor

Yokogawa compatible pH Sensor Outlasts OEM by up to 10 times 6m cable RYTON with ¾”  MNPT Front & Back End -5°C to 105°C Triple Junction (optional) Coat resistant materials reduce fouling Acid/Fluoride Resistant Ammonia, Chlorine and Sulphide Gas Resistant High Capacity KYNAR Reference Solution Ground Special glass to suit Yokogawa

GP-VIII High Temperature pH & ORP Sensor

6m cable, up to 600m optional. ¾” x 1” MNPT, PEEK Body -5°C to 135°C (optional 150°C) Fast response TC for accurate calibration Acid/Fluoride Resistant Slurry (High Abrasion) & Sulphide Resistant High Capacity KYNAR Reference Proprietary toughened glass Wide range of optional configurations Digital smart sensor technology (optional) No hard wiring – plug-n-play connectivity Sensor stores calibration data, analyser […]